PSD/4
Á¤¹Ð
¼ÒÇüÁÖ»ç±âÆßÇÁ
¸ðµâ |
|
[PSD/4
Compact
Syringe
Pump
Module] |
|
|
30
mm
Syringe
Pump |
3,000/24,000/192,000
High
Resolution |
16 Pumps Daisy-chain |
RS-232, RS-485, CAN Communication |
|
|
|
|
|
°³
¿ä |
Positive Displacement Syringe Pumps
Hamilton ÁÖ»ç±âÆßÇÁ´Â ÀϹÝÀûÀ¸·Î Á¤È®ÇÏ°Ô ½Ã·á¿Í ½Ã¾àÀ» À̼ÛÇÏ´Â ¾×üÃæÁø º¸Á¶½Ã½ºÅÛ ºÐ¾ß¿¡ »ç¿ëµÇ¸ç, Á¤¹ÐÇÑ ºÐÁÖ°¡ ÇÊ¿äÇÑ °øÁ¤ ¹× ¿¬¼ÓÀÚµ¿ºÐÁÖ¿¡ »ç¿ëµË´Ï´Ù. ÁÖ»ç±âÆßÇÁ´Â ¼ºñ½º°¡ °£ÆíÇÑ ¾çº¯À§Ä¡È¯ ¾×üÆßÇÁ·Î½á ³ôÀº Á¤¹Ðµµ¿Í ÀçÇö¼ºÀ» Á¦°øÇÕ´Ï´Ù.¾×üÀÇ ºñ¾ÐÃàÀ²¿¡ ÀÇÇØ ÁÖ»ç±âÆßÇÁ´Â Ç¥¸éÀå·Â, Á¡µµ, ½Àµµ, Á¤¼ö¾Ð, ±â¾Ð°ú °°Àº ¾×ü ȯ°æÀοäÀÎÀ¸·ÎºÎÅÍ ¿µÇâÀ» ¹ÞÁö ¾Ê½À´Ï´Ù.
ÁÖ»ç±âÆßÇÁ´Â 1ȸ¿ë ÆÁ°ú ÇÔ²²»ç¿ëÇÏ¸é ¿¡¾îº¯À§ÇÇÆê(ADP, air displacement pipetting, micro pipette)°ú °°Àº ¿ëµµ·Îµµ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. Æ©ºù¿¡ ÀÖ´Â ¾×ü´Â ½Ã½ºÅÛÀ¯Ã¼°¡ µÇ¾î ÇÇÆêÆÁÀ¸·Î ¾×ü¸¦ ÈíÀÔÇÏ°í ºÐÁÖÇÏ´Â ¿ªÈ°À» ÇÏ°Ô µË´Ï´Ù. ÀÌ·¯ÇÑ ¹æ½ÄÀ¸·Î »ç¿ëÇÒ °æ¿ì 1ȸ¿ë ÇÇÆêÆÁÀ» ¹ö¸®¸é µÇ¹Ç·Î ±³Â÷¿À¿°ÀÇ À§ÇèÀÌ ¾øÀ¸¸ç, ´ë¿ë·®ÀÇ ½Ã¾àÀ» ¿¬¼ÓÀûÀ¸·Î ºÐÁÖÇÒ ¼ö ÀÖÀ¸¸ç, ½Ã½ºÅÛÀ¯Ã¼¸¦ ¾×ü·Î ¾Ä¾î³¾¼ö ÀÖ½À´Ï´Ù.
|
Other benefits of liquid-filled positive displacement systems include:
³ª³ë¸®ÅÍ ~ ¹Ð¸®¸®ÅÍ ¹üÀ§ÀÇ ´ë¿ë·® ºÐÁÖ
°í³óµµ »ê, ¿°±â ¹× Èֹ߼ºÀ¯±â¿ë¸Å¿Í °°Àº °ÇÑ ÈÇй°ÁúÀ» ó¸®ÇÒ ¼ö ÀÖ´Â ºñÈ°¼º À¯·Î
¿¡¾îº¯À§ÇÇÆê(ADP)Àº ÇÑ °÷¿¡¼ ½Ã·á¸¦ äÃëÇÏ°í ´Ù¸¥ °÷À¸·Î À̼ÛÇÏÁö¸¸,
ÁÖ»ç±âÆßÇÁ´Â ½Å¼ÓÇÏ°Ô ´ë¿ë·®ÀÇ ½Ã·á¸¦ ¿¬¼ÓÀûÀ¸·Î ºÐÁÖ ¹ëºê¿Í ÁÖ»ç±â ¹× Æ©ºùÀÇ ±³Ã¼°¡ ¿ëÀÌ
ÇѲ¨¹ø¿¡ ¿¬¼ÓÀûÀ¸·Î ¿©·¯ °÷¿¡ ºÐÁÖÇÒ ¼ö ÀÖ½À´Ï´Ù. °¢Á¾ ¹ëºê¿Í ÁÖ»ç±â¸¦ Á¶ÇÕÇÏ¿© 󸮷® Áõ´ë
³ôÀº ¾Ð·ÂÀ¸·Î Èê·¯°¡´Â À¯Ã¼¿¡ ½Ã·á¸¦ ÁÖÀÔÇÒ ¼ö ÀÖ´Â ÁÖ»ç±âÆßÇÁ¹ëºê
¸¶ÀÌÅ©·Î À¯Ã¼ºÐ¾ß¿¡ ÀÏÁ¤ÇÑ À¯·®Á¦¾î
|
Syringe Pump Overview
Hamilton PSD Á¤¹ÐÁÖ»ç±âÆßÇÁ´Â ÃÖ°íÇ°ÁúÀÇ ¹ëºê¿Í ºñÈ°¼º ÀçÁúÀÇ ÁÖ»ç±â, ºÎ½Ä¼º ÈâÀ¸·Î ºÎÅÍ º¸È£ÇÒ ¼ö ÀÖ´Â °Ý¸®µÈ ȸ·Î±âÆÇÀ¸·Î ±¸¼ºµÇ¾î ³ôÀº ½Å·Ú¼ºÀ» Á¦°øÇÕ´Ï´Ù.
|
Superior form and function saves you money
HamiltonÀº À¯Ã¼º¸Á¶½ºÅÛÀÎ ÁÖ»ç±â, ¹ëºê, ÆßÇÁ¸ðµâÀ» ¼³°èÇÏ°í °³¹ßÇÏ°í ÀÖ½À´Ï´Ù. ÀÌ·¯ÇÑ ÅëÇÕµÈ Á¦Á¶°úÁ¤Àº ±¸¼ººÎÇ°µé °£¿¡ ¿Ïº®ÇÑ È£È¯¼ºÀ» º¸ÀåµÇ¹Ç·Î Àüü À¯´ÏÆ®·Î ¿Ï¼º¿´À» ¶§ ÈξÀ ¿ì¼öÇÑ ¼º´ÉÀ» ³ªÅ¸³»´Â °á°ú·Î ³ªÅ¸³ª°Ô µË´Ï´Ù. PSDÆßÇÁÀÇ Æ¯ÃâÇÑ ½Å·Ú¼º¿¡ ÀÇÇØ Ç°Áúº¸Áõ¼ö¸® ºñ¿ëÀ» ÁÙÀÌ°í À¯Áöº¸¼ö°è¾à¿¡ µû¸¥ ÀáÀçÀûÀÎ ÀÌÀÍÀ» ´Ã¸± ¼ö ÀÖ½À´Ï´Ù.
Hamilton ÁÖ´Â ¼º´É ÀúÇϾøÀÌ ¼ö¸íÀÌ ¿À·¡°©´Ï´Ù. PSD ÁÖ»ç±â´Â PSD ÆßÇÁ ±¸Á¶¿Í Á¤È®ÇÏ°Ô ÀÏÁ÷¼±À¸·Î ¹è¿µÇµµ·Ï ¸¸µé¾îÁ®¼ ¼ö¸íÀ» ±Ø´ëÈÇÕ´Ï´Ù.
|
|
|
|
|
Ư
¡ |
|
|
|
±Ô
°Ý |
|
PSD/4 (Half-Height Pump)
|
PSD/6 (Full-Height Pump)
|
|
|
|
General Specifications |
Accuracy:
|
± 1.0% @ 100% stroke
|
Precision:
|
+ 0.05% @ 100% stroke
|
Fluid Path:
|
Borosilicate glass, PTFE, PFA, CTFE or ceramic
|
Weight:
|
1.2 kg.
|
1.67 kg.
|
RoHS Compliant:
|
Yes
|
Linear Force Capability:
|
9.07 kgf.
|
Power Requirements |
Supply Voltage:
|
24 VDC
|
Current:
|
850 mA maximum
|
Syringe and Syringe Drive |
Syringe Volumes:
|
12.5 uL ~ 12.5 mL
|
25 uL to 50 mL
|
Syringe Materials:
|
Glass barrel, PTFE or PFA insert, stainless steel or aluminum plunger with PTFE coating, PTFE or UHMW-PE plunger tip
|
Resolution:
|
3,000 (standard) / 24,000 (high)
|
6,000 (standard) / 48,000 (high)
|
Syringe Drive Mechanism:
|
Stepper motor driven lead screw and optical encoder
|
Stroke Length:
|
30 mm
|
60 mm
|
Stringe Speeds:
|
1 second~ 50 minute/stroke
|
2 second ~ 100 minute/stroke
|
Valve and Valve Drive |
Valve Drive Speed:
|
250 ms per 120° rotation
|
Valve Drive:
|
Stepper motor with optical encoder feedback
|
Valve Fittings:
|
1/4" - 28
|
Valve Materials:
|
CTFE, PTFE or ceramic
|
Nominal Fluid Path Diameter:
|
All valves:
0.060¡± (1.524 mm) unless
otherwise noted
|
Communication |
Type:
|
RS-232, RS-485, or CAN
|
Protocols:
|
Terminal and standard
|
Baud Rate:
|
9600 or 38,400 (RS-232 or RS-485); 100,000 or 125,000 (CAN)
|
Data Bits:
|
8
|
Parity:
|
None
|
Stop Bit:
|
1, Half duplex
|
Daisy Chain Length:
|
Up to 16 individual pumps
|
Programmable Capabilities:
|
Ramps, cutoff velocity, backlash compensation, syringe speeds, loops, on-the-fly speed changes, terminate moves and delays, error detection, valve rotation selection, enhanced "h" factor capabilities including valve rotation CW and CCW
|
Environmental Operating and Storage Range |
Operating Temperature:
|
15°C ~ 40°C
|
Operating Humidity:
|
20% to 95% relative humidity, non-condensing
|
Storage Temperature:
|
-20°C ~ 65°C
|
Storage Humidity:
|
20% to 95% relative humidity, non-condensing
|
|
|
|
ÁÖ¹®Á¤º¸ |
PSD/4 (Half-Height Pump) ; The PSD/4 is the most compact Hamilton syringe pumps. It is based on half height (30 mm stroke length) syringes. This space saving design is performs all standard liquid handling functions, including dispensing, serial dispensing and diluting.
PSD/4 Pumps |
|
PSD/4 Standard
|
54848-01
|
PSD/4 Smooth Flow
|
97709-01
|
PSD/4 High Lift Force
|
99193-01
|
PSD/4 High Valve Torque
|
99194-01
|
PSD/4 High Valve Torque and Lift Force
|
99195-01
|
PSD/4 Starter Kit |
|
Demo Communication Cable for PSD/4, MVP/4 and PSD/6
|
57025-01
|
Starter Kit for the PSD/4, MVP/4 and PSD/6
|
64316-04
|
PSD/4 Type Specifications |
Highest Resolution (steps/stroke) |
Fastest/Slowes (time/stroke) |
|
Linear Force Capability (lbf) |
Valve Torque Capability (in oz) |
|
Standard |
|
|
|
|
|
|
Smooth Flow |
|
|
|
|
|
|
High Lift Force |
|
|
|
|
|
|
High Valve Torque |
|
|
|
|
|
|
High Valve Torque & Lift Force |
|
|
|
|
|
|
|
PSD/4 Syringes ; Syringes for the PSD/4 syringe pump are available with a standard PTFE-tipped plunger and with a long life UHMWPE (Ultra High Molecular Weight Poly Ethylene) plunger tip. The stroke length of a PSD/4 syringe is 30 mm.
* Not compatible
with 57252-01, 58889-01, 8778-01, 7992-01,
and 7993-01. ** Not compatible with
7992-01 and 7993-01. Use valve 59943-01
as a substitute for 7993-01.
|
PSD/4 Valves ; The PSD/4 is a compact syringe pump designed to perform all liquid handling operations including dispensing and diluting. The modules can be fitted with a choice of valves to meet even the most demanding applications.
Flow Daigram |
Description
|
Model
|
Ceramic
|
PTFE
|
|
"Y" Flow Path
2-ports, plus syringe port
|
Y-Valve
|
8778-01
|
57252-01
|
|
Y-Block
Static non-switching Y-block
|
Y-Block
|
NA
|
9537-01
|
|
"T" Flow Path
2-ports, plus syringe port
|
3-3
|
8063-01
|
58889-01
|
|
Distribution Flow Path
3-ports, plus syringe port
|
3-5
|
7991-01
|
NA
|
|
90° Flow Path
3-ports, plus syringe port
|
4-2
|
9234-01
|
NA
|
|
Distribution Flow Path
4-ports, plus syringe port
|
4-5
|
7992-01
|
NA
|
|
Distribution Flow Path
6-ports, plus syringe port
|
6-5
|
9998-01
|
NA
|
|
Distribution Flow Path
8-ports, plus syringe port
|
8-5
|
7993-01
59943-01
|
|
|
|
|
|
|
±ÍÇÏÀÇ
¼º°øÀûÀÎ ¿¬±¸°³¹ßÀÇ µ¿¹ÝÀÚ°¡ µÇ°Ú½À´Ï´Ù.
|
18/10/12
|
|